Features:
- Voltage, resistance, continuity, capacitance
- Input terminal for ac and dc current measurements to 10 A and current
- Backlit display
- Data hold
- Diode test, plus frequency and duty cycle measurements
Specification:
Accuracy is specified for 1 year after calibration, at operating temperatures of 18
Features:
- Voltage, resistance, continuity, capacitance
- Input terminal for ac and dc current measurements to 10 A and current
- Backlit display
- Data hold
- Diode test, plus frequency and duty cycle measurements
Specification:
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] [Number of Least Significant Digits])
Accuracy Specifications | ||||
AC Volts (40 Hz to 500Hz)1 | Range | Resolution | Accuracy | |
6.000 V60.00 V600.0 V | 0.001 V0.01 V0.1 V | 1.0 % 3 | ||
DC Volts | 6.000 V60.00 V600.0 V | 0.001 V0.01 V0.1 V | 0.5 % 3 | |
AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % 3 | |
Diode Test2 | 2.000 V | 0.001 V | 10 % | |
Resistance (Ohms) | 400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ | 0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ | 0.5 % 30.5 % 20.5 % 20.5 % 20.5 % 21.5% 3 | |
Capacitance3 | 50.00 nF500.0 nF5.000 μF50.00 μF500.0 μF1000 μF | 0.01 nF0.1 nF0.001 μF0.01 μF0.1 μF1 μF | 2 % 52 % 55 % 55 % 55 % 55 % 5 | |
Frequency4Hz(10 Hz – 100 kHz) | 50.00 Hz500.0 Hz5.000 kHz50.00 kHz100.0 kHz | 0.01 Hz0.1 Hz0.001 kHz0.01 kHz0.1 kHz | 0.1 % 3 | |
Duty Cycle4 | 1 % to 99 % | 0.1 % | 1 % typical 5 | |
AC Current(40 Hz to 200 Hz) | 4.000 A10.00 A | 0.001 A0.01 A | 1.5 % 3 | |
DC Current | 4.000 A10.00 A | 0.001 A0.01 A | 1.5 % 3 | |
| ||||
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
AC Volts | 600 V 1 | >10 MΩ <100 pF 2 | >60 dB at dc,50 Hz or 60 Hz | − |
AC Millivolts | 600 mV | >1M, <100 pF | >80 dB at 50 Hz or 60 Hz | − |
DC Volts | 600 V 1 | >10 MΩ <100 pF | >100 dB at dc,50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz |
| ||||
General Specifications | ||||
Maximum Voltage Between any Terminal and Earth Ground | 600 V | |||
Display (LCD) | 6000 counts, updates 3/sec | |||
Battery Type | 2 AAA, NEDA 24A, IEC LR03 | |||
Battery Life | 200 hours minimum | |||
Temperature | ||||
Operating | 0 °C to 40 °C | |||
Storage | -30 °C to 60 °C | |||
Relative Humidity | ||||
Operating Humidity | Non-condensing when <10°C≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C | |||
Operating Humidity, 40 MΩ Range | ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C | |||
Altitude | ||||
Operating | 2000 m | |||
Storage | 12,000 m | |||
Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) | |||
Fuse Protection for Current Inputs | 11A, 1000V Fast Fuse, Fluke specified part only | |||
Size (HxWxL) | 142 mm x 69 mm x 28mm | |||
Weight | 200 g | |||
IP Rating | IEC 60529: IP 40 | |||
Safety | IEC 61010-1: 600 V CAT III, Pollution Degree 2 | |||
Electromagnetic Environment | IEC 61326-1: Portable | |||
Electromagnetic Compatibility | Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1 | |||
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. |