Specification:
- Working voltage: DC12V
- Working frequency: 315MHZ
- Max current load: 10A
- Receiver sensitivity: -100DB
- Encoding type: Learning code
Specification:
- Working voltage: DC12V
- Working frequency: 315MHZ
- Max current load: 10A
- Receiver sensitivity: -100DB
- Encoding type: Learning code
- Jog: Press one button is working, loosen your finger on the same button is stop .need one channel switch and one button remote control)
- Self -lock: Press one button for one time is working. press the same button again is stop. (Need one channel switch and one button remote control)
- Inter-lock: Press one button is working, press another button is stop. (Need one channel switch and 2 buttons remote control
- (Special note: Switching working mode need to disconnect the power first)
- 1. The input terminal is V, connect 12V positive.
- 2. The input terminal is GND, connect 12V negative.
- 3. The board marked NC-1 (normally closed end), COM-1 (common), NO-1 (normally open) is a set of three outputs relay (output is switching signal);
- 4. The board marked NC-2 (normally closed end), COM-2 (common), NO-2 (normally open) is a set of three outputs relay (output is switching signal);
- 5. Set the output mode: Position JP2 has jumper caps, please plug it before power. After the jumper is plugged (in accordance to 6,7,8), the output state is setting successful. (Note: The output state is determined before power, if you change jumpers after power, will does not change its output function)
- 6. Set the output mode to: Jog! jumper to 1,2 port (shorted both ports), output mode is instantaneous (Jog); Press the remote control button, the relay will pull, release the remote control button, the relay is released; need another two key remote control (package is not included).
- 7. Set the output mode to: Self-locking! jumper to 1,2 port (shorted both ports), the output mode is steady-state (self-locking); Click the remote control button, the corresponding relay of this group pull in, then click the remote control button again, the corresponding of this group relays disconnect; need another two key remote control (package is not included).
- 8. Set the output mode to: Interlock! Pull out the jumper; Output way: interlocking, press the A button on the remote control, relay group 1 pull in, press button B, relay group 2 pull in, group 1 disconnect, two relays are presented interlocked state. Press the C button, two relays are disconnected; need another three key remote control (package is not included).
- 1 x Wireless Transmitter Receiver